Photometrics Mode
This
operation mode can be used for routine analysis of samples and features:
·
Wavelength selection over the entire wavelength range
of 198nm-1000nm
·
Simultaneous quad-display of Concentration, Absorbance,
% Transmittance, and Wavelength
for
easy direct reading
·
Selectable Concentration units, for greater versatility
including: m g/ml, mg/l, g/l, mg/l, ppm, mM,
M,
%, ng/ml, mg/ml or can be left blank
On-board RNA/DNA Analytical Software
Stored
in the permanent memory are the wavelengths, calculations and factors necessary for analysis of proteins, DNA/RNA, and oligonucleotides.
Corrections can be made by subtraction at a third wavelength and multiplication by factors. A variable ratio mode allows the
user to change the wavelengths and factors allowing for fine adjustment and greater accuracy. The Genova is also ideal for
OD 600 bacterial measurements.
On-board Protein Analytical Software
Protein
methods include Bradford,
Lowry, Biuret, Biccinchonic, and direct UV methods. Measurement is by standard curve and can be accomplished by calibration
of up to 6 standard solutions or by manual entry. The curve can be viewed as a graphic or as a data list, while statistics
show the terms used for the calculated quadratic curve fit. When analyzing an unknown sample against the curve, a tri-display
of wavelength, concentration and absorbencies is easily read on the large LCD. The protein software also features a direct
UV mode that does not use a calibration curve, but utilizes readings at 280nm and 260nm.
Method Storage
Allows
the user to save up to 10 protein calibration curve methods, for easy recall. The method settings and the last date and time
the method was modified are simultaneously displayed.
Purity Scans
This
mode allows a user to optimize measurements by zeroing in on peak absorbance wavelengths. Scans can be performed over the
entire wavelength range of 198 to 1000nm, in increments of 100nm at 1nm intervals. An easy to read graphical representation
of absorbance versus wavelength is displayed, with a final statistical display of peak absorbance and wavelength. A hard copy
printout can be obtained by one touch of the print key.
RS232 and Analogue Outputs
The
RS232 port allows the user to print data out directly or download data to a PC through HyperTerminal with a single touch of
the print key.
Security Lock
The
instrument lock mechanism prevents operating parameters of the unit from being changed and is protected by a three digit locking
code.
Self-Calibration
Upon
startup, a self-calibration test is performed at 3-wavelengths, 247nm, 528nm, and 824nm to ensure G.L.P. (Good Laboratory
Practice) compliant operation. If the unit does not pass the test, a message will be displayed.
Versatile Sampling System
The
Genova is standard with a 10 x 10mm cuvette holder. Accessories can be easily interchanged and include:
·
Sipper system
·
4-positon cell holder
·
Test tube holders that hold 13mm, 25mm, and 16mm tubes
·
20-100mm cell holder
Small
Footprint
The
unit is only 10.3 inches wide, 7.6 inches deep, 4.5 inches high, and weighs only 13 pounds. It saves valuable bench space
and can be easily moved around the lab or a department.
Xenon Lamp
The
xenon lamp is a long lasting, high-energy lamp that is covered by a one year warranty.