65 SERIES SCANNING SPECTROPHOTOMETERS
jenway6505.jpg
The Model 6500 Visible Range Spectrophotometer is the new 1.8nm band pass scanning spectrophotometer available  from Edu-Chem.   Photometrics, Spectrum, Multi-wavelength, Quantitation, Kinetics and Method  Storage are implemented in the 6500. Wavelengths are selectable between 320 and 1100nms at 0.1nm intervals.

The Model 6505 UV Visible Range Spectrophotometer offers all the above features in the 6500 but with increased scanning range of 190nm - 1100nm through the use of a deuterium lamp.

Download PDF Product Sheet

Request a Quote or Information

 

Features and Benefits

Wide Range of operation - The Model 6500 Visible Spectrophotometer can be used between 320 and 1100nms (at 0.1 nm intervals), while the Model 6505 UV/Visible Spectrophotometer extends this range to between 190 and 1100nms (at 0.1nm intervals). Photometrics, Spectrum, Scanning, Multi-wavelength, Quantitation and Kinetic measurements are all implemented in a user friendly manner.

Graphics Display - Both models feature ¼ VGA back lit monochrome LCD giving a clear readout of calibration data, sample data and all set-up options.

Keypad - A simple, easy to use, keypad facilitates setting experimental parameters and initiating sample analysis procedures.

Lamp Housings - A removable rear panel allows easy access to the Halogen lamp (on both instruments) and the Deuterium lamp (on the Model 6505).

Sample Compartment - A large compartment is fitted to the instrument to house the full range of accessories developed for the 6500 series. Various sizes of quartz, glass and plastic cuvettes are available for sample volumes down to 50µl.

Printer - A 40 column impact mechanism printer can be fitted to either instrument to allow a hard copy of all readings to be produced. The printer is capable of reproducing spectrum, kinetics and quantitation scans graphically for future reference along with appropriate statistics. The 6500 series also includes a Centronics Parallel Port drives a IBM PC compatible desktop printer.  

Good Laboratory Practice - This is supported by a series of features. A user set identification number is be entered into any instrument (up to 20 digits in length) and this number will appear on any printouts produced by the instrument. Also contained on each printout is a sample number, the sample reading, the units of measurement, the wavelength of analysis and the current time and date. The instruments are supported by traceable calibration standards to provide the on-going accuracy required for Good Laboratory Practice protocols. Each unit carries the CE mark and is covered by a three year warranty. NOTE: The deuterium lamp is warranted for 1 year.

Data Handling and Interfacing - Both instruments incorporate a bi-directional RS232 interface allowing remote operation, calibration and interrogation by an external personal computer. This operates over a fixed baud rate of 1200 bits per second. Results can be downloaded to a personal computer by a single touch of the print key. 

Automatic Results Log - Readings can be stored in a data file when the print key is pressed or at a user set time interval or by a multiple sample assay using the eight position cell holder. Data files have a user entered identification and can be saved in the instruments internal memory or to a data memory card. Results saved in the instruments memory can be transferred to a memory card. Both the internal memory and data memory card have a 1 megabyte capacity and can store up to 50 spectral/kinetics/quantitative scans.

Method Storage -  Method storage allows all user set parameters to be saved against a user identification. A method can be subsequently recalled which configures the instrument (including operating mode) to the saved parameters. The instrument settings settings for a recalled method can be altered and subsequently saved against the same or a different method identification. Methods can be saved in the instruments internal non-volatile memory or to a data memory card. Methods saved in the instruments memory can be transferred to a memory card. The instruments memory has the capacity to store a minimum of 50 methods.



Enter content here


SPECIFICATIONS

 

Model 6500

Model 6505

Wavelength

 

 

Range

320 to 1100nm

190 to 1100nm

Resolution

0.1nm

0.1nm

Accuracy

±1nm

±1nm

Bandwidth

1.8nm

1.8nm

Transmittance

 

 

Range

0 to 199.9%

0 to 199.9%

Resolution

0.1%

0.1%

Absorbance

 

 

Range

-0.300 to 3.000A

-0.300 to 3.000A

Resolution

0.001A

0.001A

Concentration

 

 

Range

-300 to 9999

-300 to 9999

Resolution

0.001 / 0.01 / 0.1 / 1

0.001 / 0.01 / 0.1 / 1

Factor

 

 

Range

0.000 to 9999.99

0.000 to 9999.99

Photometric Linearity

0.005A @ 1.0A

0.005A @ 1.0A

Stray Light

0.05%T @ 340nm

0.05%T @ 340nm

Drift

0.001A per hour

0.001A per hour

Display

¼ VGA back lit monochrome LCD 320 x 240mm

¼ VGA back lit monochrome LCD 320 x 240mm

RS232 port

Bi-directional

Bi-directional

Internal Memory

1 mB size- 50 methods and 50 scans

1 mB size- 50 methods and 50 scans

Analog output

1mV per 0.1% Transmittance
1mV per 0.001 Absorbance
1mV per 1 Concentration unit

1mV per 0.1% Transmittance
1mV per 0.001 Absorbance
1mV per 1 Concentration unit

Visible Light Source

Tungsten Halogen lamp

Tungsten Halogen lamp

UV Light Source

 

Deuterium lamp

Input Voltage

115V AC / 230V AC ±20%

115V AC / 230V AC ±20%

Input Power

<150W

<150W

Operating temperature

15 to 30ºC

15 to 30ºC

Operating humidity

0 to 90% RH

0 to 90% RH

Weight

15Kg

15Kg

Warranty*

3 year parts and labor
*(tungsten lamp no warranty, xenon and deuterium lamps 1 year)