An advanced measuring system with modes for Photometrics, Concentration, Quantitation, Kinetics and Scanning. The 6310 will meet the demands of a wide range of applications, especially those in the clinical, veterinary, environmental, general QC and performance testing areas. With a memory capacity of 50 methods for each mode, the fully open operating system ensures compatibility  with reagent kits from most manufacturers, as well as enabling full customization to the operator's choice of chemistries and operating procedures.

  • Photometric measurements in Absorbance and Transmittance
  • Concentration measurement by direct factor entry or against blank and standard
  • Quantitation using up to 6 standards - with curve correction and correlation coefficient
  • Kinetics with real time graphical display of sample and standard runs
  • Spectrum - scanning any range from 320-1000nm
  • Store up to 50 methods in each mode

Features include:

Simple keypad layout and novel customizable menus ensure reliable operation by unfamiliar users.

Supervisor Security functions, when activated, enable all the set up options to be locked. These cannot be changed without the entry of a security code number.

Simultaneous display of Absorbance, Transmission and Wavelength in the Photometrics mode means that manual range changing is not necessary.

Simple concentration measurements using a single standard or factor can be made in the concentration mode. The Quantitation mode allows more complex concentration methods to be programmed, using up  to 6 standards to create a calibration curve. For each curve fit option a linearity correlation coefficient is calculated.

A real-time graphical display of Kinetic measurement is shown, along with the calculated concentration value and other relevant data.

The Spectrum Scanning mode allows scans to be made across and selected portion of the 320-1000nm range. The auto-ranging Absorbance axis allows scans to be commenced with no prior knowledge of the peak Absorbance level expected.

The 6310 has an analogue output that can be used to drive chart recorders and other analogue recording  or conversion devices.

A bi-directional RS232 serial port allows connection to serial printers and computers.

The included 63-Ten software allows full emulation of the instrument functions on a PC, including the importing of results and download of methods.

An electrically heated cuvette holder and control unit is available, as well as a water heated cuvette holder and a thermostatically controlled water circulator. The external,programmable sipper pump ensures faster and safer sample handling.

The large sample compartment enables a wide range of sampling devices to be fitted. Cuvette holders from 10 to 100mm in path length, a 4 position rotary cuvette holder and test tubes from 12.5 to 25mm can all be accommodated.

 

Optics

Single beam

Wavelength range

320-1000nm

Resolution

1nm

Accuracy

±2nm

Bandwidth

8nm

Transmittance range

0 to 199.9%

Resolution

0.1%

Accuracy

±1%T

Absorbance range

-0.300 to 1.999A

Resolution

0.001A

Concentration range

-300 to 1999

Selectable resolution

1/0.1/0.01/0.001

Calibration

Blank with a single standard or factor

Memory

50 methods

Quantitation

-300 to 1999Conc

Selectable resolution

1/0.1/0.01/0.001

Calibration

Blank with up to 6 standards

Curve Correction

Linear regression, interpolation or linear regression through zero

Memory

50 methods

Kinetics

Graphical and calculated concentration value

Calibration

Against standard and factor

Correlation factor

r squared value displayed with result

Memory

50 methods and 5 graphed results

Spectrum

Any range between 320 and 1000nm

Scan data interval

1, 2 or 5nm selectable

Analysis

Absorbance and wavelength of paks and velleys

Memory

50 methods and 5 scans

GLP

Real time clock and calendar
Operator ID
Supervisor security (locks all set up parameters)
Method display lock

Photometric noise levels

<1%

Photometric stability

Better than 1%/hr

Readout

Custom LCD

Outputs

Analogue / RS232 serial port

Input voltage

115/230V a.c. -20% +10% 50/60Hz

Input power

<50W

Size (inches)

14 x 11 x 6

Weight

6Kg